Server Technology Switched POPS PDU - 5.0kW, C2WG12SM-2CJA2D3

Part No. C2WG12SM-2CJA2D3

by Server Technology, Inc

Server Technology Switched POPS PDU - 5.0kW, C2WG12SM-2CJA2D3

Switched - NEMA L6-30P - 9 x IEC 60320 C13, 3 x CX - 230 V AC - Network (RJ-45) - 1U - Rack-mountable

Part No. C2WG12SM-2CJA2D3

by Server Technology, Inc

$2760.99
General Information
ManufacturerServer Technology, Inc
Manufacturer Part NumberC2WG12SM-2CJA2D3
Brand NameServer Technology
Product SeriesPRO2
Product ModelC2WG12SM-2CJA2D3
Product NameSwitched POPS PDU - 5.0kW, C2WG12SM-2CJA2D3
Marketing InformationThe Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Master" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
Product TypePDU
Technical Information
PDU TypeSwitched
PhaseThree Phase
Plug/Connector TypeNEMA L6-30P
Receptacle Type
  • IEC 60320 C13
  • CX
Receptacle Detail
  • 9 x IEC 60320 C13
  • 3 x CX
Protection Type
  • Fuse
  • Double Pole
Power Description
Input Voltage230 V AC
Output Voltage230 V AC
Power Rating (Watt)5 kW
Input Current30 A
Management
Management
  • SSH
  • SMTP
  • Syslog
  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c and v3 (GET, SET, Traps)
  • IPv4 and IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mount TypeRack-mountable
Rack Height1U
Height1.75" (44.45 mm)
Width17.20" (436.88 mm)
Depth11.57" (293.88 mm)
Miscellaneous
Country of OriginUnited States
ConditionNo
Warranty
Limited Warranty2 Year
miscellaneous kits (2)

Part No. KIT-0020

Server Technology (KIT0020) Miscellaneous Kits

LEGRAND MOUNTING BUTTON KIT

Part No. KIT-PRO2LINK-01D

Server Technology (KIT-PRO2LINK-01D) Miscellaneous Kit

Legrand-Servertech PRO2 Multi-Linking (Dongle) Kit, (1) Detached Link Module, (2) 6.4 m / 21 ft linking Cables, (1) 305 mm (1 ft) PDU to Module Cable

temperature & humidity sensors (2)

Part No. EMCU-1-1C

Server Technology (EMCU11C) Temperature & Humidity Sensors

LEGRAND ENVIRONMENTAL MONITOR CONTROL UNIT SUPPLIED WITH ONE (1) TEMPERATURE ANDHUMIDITY PROBE (PART NUMBER EMTH-2-10) WITH 10 FT (3 M) CORD, STI

Part No. EMTH-2-10

Temp & Humidity Probe

LEGRAND-SERVERTECH COMBO TEMP & HUMIDITY PROBE