APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

Part No. APDU10350SM

by Schneider Electric SA

APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

Switched - IEC 60309 30A 3P+N+PE - 24 x IEC 60320 C13/C15/C19/C21, 24 x IEC 60320 C13/C15 - 415 V, 480 V - Network (RJ-45) - 5.9 ft (1.80 m) Cord Length - 0U - Vertical - Rack

Part No. APDU10350SM

by Schneider Electric SA

$5696.99
General Information
ManufacturerSchneider Electric SA
Manufacturer Part NumberAPDU10350SM
Brand NameAPC by Schneider Electric
Product LineNetShelter
Product NameNetShelter 48-Outlets PDU
Marketing Information

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Product TypePDU
Technical Information
PDU TypeSwitched
PhaseThree Phase
Plug/Connector TypeIEC 60309 30A 3P+N+PE
Receptacle Type
  • IEC 60320 C13/C15/C19/C21
  • IEC 60320 C13/C15
Receptacle Detail
  • 24 x IEC 60320 C13/C15/C19/C21
  • 24 x IEC 60320 C13/C15
Power Description
Input Voltage
  • 415 V
  • 480 V
Input Voltage Range
  • 200 V AC - 240 V AC
  • 346 V AC - 415 V AC
Output Voltage240 V AC
Power Rating (VA)17.30 kVA
Power Rating (Watt)17.30 kW
Input Current30 A
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Color FamilyBlack
Product ColorBlack
Mounting OrientationVertical
Mounting PreferenceNo Preference
PlacementSide
Form FactorRack
Rack Height0U
Cord Length5.9 ft (1.80 m)
Height70.08" (1780 mm)
Width2.20" (56 mm)
Depth2.95" (75 mm)
Weight (Approximate)21.16 lb (9598.01 g)
Miscellaneous
For Country/RegionUnited States
Certifications & Standards
  • UKCA Compliance
  • TAA Compliance
  • BAA Compliance
  • Product Take Back ProgramNo
    RoHS Exemption Informationhttps://download.schneider-electric.com/files?p_enDocType=Declaration+of+Conformity+%28Sustainability%29&p_Doc_Ref=APDU10350SM_ROHS_DECLARATION&p_FileName=APDU10350SMKIT_ROHS_DECLARATION_US.pdf
    REACH Declaration URLhttps://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfReach&pid=552063000&lang=en-us
    EU RoHS Declaration URLhttps://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=552063000&lang=en-us
    Environmental Profile Availabilityhttps://download.schneider-electric.com/files?p_enDocType=Environmental+Disclosure&p_Doc_Ref=ENVPEP1612035_V1
    End of Life Manual Availabilityhttps://download.schneider-electric.com/files?p_enDocType=Circularity+Profile&p_Doc_Ref=ENVEOLI1612033_EN
    WEEE StatementThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Country of OriginIndia
    Environmentally FriendlyYes
    Environmental ComplianceRestriction of Hazardous Substances (RoHS)
    ConditionNo
    UPC0731304439745
    Warranty
    Limited Warranty3 Year

    Part No. WEXWAR1Y-AC-05

    Warranty extension, for accessory, renewal or high volume, 1 yr, level 05 - 24 x 7 - Technical

    1 Year Warranty Extension for (1) Accessory (Renewal or High Volume)